EDBM: Pilot unit for bipolar electrodialysis
EDBM: Pilot unit for bipolar electrodialysis
Batch unit with 0.5 - 1 sqm membrane area
Typical configuration: The PCCell EDBM pilot units operates a ED Q380 stack with bipolar membranes and comprises three solvent circuits plus electrolyte circuit.
Application profile:
The unit is operated by our PC Frontend and handles typically 30 L batches. End points can be determined automatically and combined with our pneumatic valves, small industrial production batches can be performed.
Sizes: |
|
|
Size (whd): |
1700 x 1680 (2000) x 800 mm |
|
Active membrane area: |
0.5 - 1 sqm |
|
Power Connector: |
400 V 50 Hz |
|
Batch volumes: |
30 l |
|
Electrolyte tank volume: |
30 l |
Processing capabilities: |
|
|
Product flows: |
50 - 200 l / h |
|
Current through cell: |
max 38 A (optional: max 75 A) |
Standard features: |
|
|
PCCell PC Frontend with process control and data looging to your computer |
|
pH and conductivity measurement |
|
Pneumatic valves with automatic batch processing |
|
automatic dosing of chemicals to maintain pH or conductivity |