PCCell GmbH
PCCell GmbH Lebacher Strasse 60 66265 Heusweiler Germany

EDBM: Pilot unit for bipolar electrodialysis

EDBM: Pilot unit for bipolar electrodialysis

Batch unit with 0.5 - 1 sqm membrane area

Typical configuration: The PCCell EDBM pilot units operates a ED Q380 stack with bipolar membranes and comprises three solvent circuits plus electrolyte circuit.

Application profile:
The unit is operated by our PC Frontend and handles typically 30 L batches. End points can be determined automatically and combined with our pneumatic valves, small industrial production batches can be performed.

Sizes:  
  Size (whd): 1700 x 1680 (2000) x 800 mm
  Active membrane area: 0.5 - 1 sqm
  Power Connector: 400 V 50 Hz
  Batch volumes: 30 l
  Electrolyte tank volume: 30 l
Processing capabilities:  
  Product flows: 50 - 200 l / h
  Current through cell: max 38 A (optional: max 75 A)
Standard features:  
  PCCell PC Frontend with process control and data looging to your computer
  pH and conductivity measurement
  Pneumatic valves with automatic batch processing
  automatic dosing of chemicals to maintain pH or conductivity


 

PCCell GmbH
Lebacher Strasse 60
66265 Heusweiler / Germany
Phone:
Fax:
E-mail: 
+49 6806 603732
+49 6806 603731
webcontact@pccell.de