Homepage of PCCell Contact Details Order and Request Site Map home of PCCell e-mail ED Process control Order/Request Ion Exchange Membranes --> PCA GmbH Downloads zum Seitenanfang zum Seitenanfang

 

Electrodialysis Module PCCell 1600

back to produt-overview

View of an electrodialysis cell.
Type PCCell ED 1600
PCCell.technical info:
Two Chamber Electrodialysis Cell
Sizes:  
Membrane size: 400 x 460 mm.
Active membrane area: 1600 sqcm per membrane.
Processing length: 40 mm.
Spacer thickness: 0.32 mm (chemical process).
Number of cell pairs: up to 200.
Materials:  
Anode: Pt/Ir- coated Titanium.
Cathode: V4A Steel.
Electrode housing material: Polypropylene.
Optional features:  
Electrodialysis reversal (EDR).
All medium contacting materials food proof.

 

Application profile: This electrodialysis module covers membrane areas from 20 - 40 sqm in a very lightweight skid and is intended to perform acid recovery and food applications.

Please mail us to request an offer under e.cells pccell.de or use our request form.

zum Seitenanfang